sales@evoluxfiber.com    +86-755-28169892
Cont

Puas muaj lus nug?

+86-755-28169892

Fiber Optic Mu Patchcord SM SX YELLOW
video
Fiber Optic Mu Patchcord SM SX YELLOW

Fiber Optic Mu Patchcord SM SX YELLOW

Fiber Optic MU Patchcord muab cov kev daws teeb meem tshiab rau siab -kev sib txuas lus kev sib txuas lus. MU connector yog tsawg kawg yog ib nrab ntawm qhov loj ntawm tus qauv SC connector, muab ob zaug ntawm qhov chaw nres nkoj ceev thaum tuav tag nrho cov kev ua tau zoo ntawm cov khoom siv fiber ntau optic.
Xa kev nug

Khoom Taw qhia

Fiber Optic MU Patchcordmuab cov kev daws teeb meem tshiab rau kev ua haujlwm siab -kev sib txuas lus hauv xov tooj. MU connector yog tsawg kawg yog ib nrab ntawm qhov loj ntawm tus qauv SC connector, muab ob zaug ntawm qhov chaw nres nkoj ceev thaum tuav tag nrho cov kev ua tau zoo ntawm cov khoom siv fiber ntau optic. MU system suav nrog ntau hom kev xaiv ntau hom thiab ib hom kev xaiv, ua rau nws yog qhov kev xaiv zoo tshaj plaws rau kev tsim kho tshiab niaj hnub.

 

Vim li cas thiaj xaiv US?

 

  • Cov khoom ntawm Superior Quality: Kev ntseeg siab thiab ruaj khov yog lav los ntawm qhov siab -kev tsim khoom zoo ntawm pebFiber Optic MU Patchcords.
  • Tus nqi -Txoj kev xaiv tau zoo: Peb cov nqi sib tw yam tsis muaj kev cuam tshuam zoo.
  • Kev xa khoom sai: Peb paub tseeb tias koj cov xaj xaj xa khoom sai vim peb paub tias nws tseem ceeb npaum li cas kom tau txais lawv rau koj raws sijhawm.
  • Kev Pabcuam Kev Pabcuam: Kev taw qhia kev teeb tsa thiab kev txhawb nqa yog muaj los ntawm peb pab pawg kws tshaj lij.

 

Khoom Specifications

 

Txuas

MU

Fiber suav

Simplex / Duplex

Fiber hom

9/125;50/125;62.5/125

Yam tsawg kawg nkaus Khoov Radius

10 mm

Polish Hom

APC/UPC

Cable Diameter

0.9 hli / 2.0mm / 3.0mm

Cable Jacket

PVC/LZH

Jacket Xim

Daj / Txiv kab ntxwv / OM3 / OM4

Lub wavelength

1310nm / 1550nm

Durability

500 zaug

Insertion Loss

Tsawg dua lossis sib npaug li 0.3 dB

Hloov pauv tau

Tsawg dua lossis sib npaug li 0.2 dB

Rov Los Los

Ntau dua lossis sib npaug li 60 dB

Kev vibration

Tsawg dua lossis sib npaug li 0.2 dB

Ua haujlwm kub

-40 ~ 75 degree

Cia Kub

-45 ~ 85 degree

 

Khoom nta

 

  • NTT-MU Hardware Compatibility: Ua kom muaj kev sib haum xeeb nrog NTT-MU kho vajtse.
  • NTT & JIS Kev Ua Raws Cai: Ua tau raws li thoob ntiaj teb thiab cov qauv kev lag luam rau kev ua tau zoo thiab kev ua haujlwm.
  • Compact, rub-Proof Design: Durable thiab txhim khu kev qha, tsim los tiv thaiv ib puag ncig nyuaj.
  • 100% Optically Inspected thiab Tested: Txhua patchcord yog kuaj rau qhov poob los xyuas kom meej kev ua tau zoo.
  • Riser lossis Plenum Rated: Muaj nyob rau hauv ntau hom cable, suav nrog PVC, OFNR, LSZH, thiab RoHS.
  • Kev poob qis qis thiab rov qab poob siab: Ua raws li IEC, TIA / EIA, thiab Telcordia cov qauv.
  • Kev Cai Fiber Optic Cable Lengths thiab Jacket Xim: Ua kom haum rau koj cov kev xav tau tshwj xeeb.
  • Ntau Hom Fiber thiab Wavelengths: Txhawb singlemode thiab multimode fibers, suav nrog OM2, OM3, thiab OM4.
  • Kev ntim khoom zoo, Tus nqi sib tw, thiab xa khoom sai: Ua kom muaj kev ntxhov siab - kev paub txog kev yuav khoom dawb.

 

Ob hom Polish rau ntau yam teeb liab rhiab heev xav tau

Lub ntsej muag fiber ntau ntawm APC yog polished ntawm 8℃kaum sab xis thiab UPC polished tsis muaj lub kaum sab xis.

product-914-185

UPC feem ntau yog siv rau TV, xov tooj thiab cov ntaub ntawv. APC feem ntau yog siv rau FTTX, PON thiab lwm yam WDM systems.

 

Peb txoj kab uas hla kom tau raws li cov kev xav tau sib txawv

3.0mm, 2.0mm thiab 0.9mm cable diameters yog siv rau sab hauv tsev installation thiab cabling.

product-900-322

 

Kev Tswj Xyuas Zoo

 

Ntawm Shenzhen Evolux Fiber Co., Ltd, peb tuav nruj tswj kev ntsuas kom ntseeg tau tias txhuaFiber Optic MU Patchcordua tau raws li tus qauv siab tshaj plaws. Peb cov txheej txheem tsim khoom muaj xws li:

  • Kev tshuaj xyuas cov khoom: Tag nrho cov ntaub ntawv raw yog tshuaj xyuas ua ntej siv.
  • Hauv -Txoj Kev Tshawb Fawb: Kev soj ntsuam tas li thaum lub sijhawm tsim khoom kom ntseeg tau tias muaj kev sib xws.
  • Kev soj ntsuam zaum kawg: Txhua yam khoom tau raug soj ntsuam zaum kawg kom ntseeg tau tias nws ua tau raws li peb cov qauv zoo.

 

Kev Pabcuam OEM

 

Peb muab kev pabcuam OEM, suav nrog:

  • Kev Cai Branding: Ntxiv koj lub tuam txhab logo thiab cov npe rau peb cov khoom.
  • Custom Packaging: Tailor lub ntim rau koj specifications.
  • Private Labeling: Tsim ib daim ntawv lo rau koj hom.

 

Daim ntawv thov

 

DWDM/CWDM Systems - High-Density WDM Applications

DWDM/CWDM Systems

  • Dense wavelength division multiplexing khoom
  • High -nruab nrab qhov sib txuas sib txuas
  • MAN thiab WAN qaum tes hauj lwm
  • Ntev -haul kis systems (1310nm / 1550nm)
High-Density Data Center Patching

High-Density Data Centers

  • Qhov chaw - txwv thaj chaw thaj chaw ib puag ncig
  • 2x chaw nres nkoj ceev vs. SC connectors hauv tib hneev taw
  • Storage area network (SAN) hla -kev sib txuas
  • 1G / 10G Ethernet server kev sib txuas
Telecommunications Central Office

Telecommunications Networks

  • NTT- kev sib koom ua ke ntawm cov khoom siv network txheem
  • Optical distribution thav duab (ODF) patching
  • Lub suab network optical kis tau tus mob
  • Carrier -qib kev tsim kho vaj tse
Test Equipment and Lab Environments

Kev Ntsuas & Ntsuas

  • OTDR thiab kho qhov muag fais fab ntsuas kev sib txuas
  • R & D kuaj fiber ntau
  • Siv tus qauv cable rau kev ntsuas poob
  • Industrial thiab tub rog optical systems

FAQ

 

Q: Dab tsi yog qhov MU connector, thiab nws txawv ntawm SC lossis LC li cas?

A: Cov lus nug zoo - qhov no tshwm sim ntau heev! MU connector yog tsim los ntawm NTT hauv Nyiv thiab yog qhov tseem ceeb "mini SC" - nws siv tib lub laub- rub mechanism li SC, tab sis nrog 1.25mm zirconia ferrule es tsis txhob siv 2.5mm ferrule siv hauv SC connectors. Qhov ntawd txhais tau tias koj tuaj yeem haum ob MU channel hauv tib lub hneev taw raws li ib qho SC txuas. Piv rau LC, MU muaj qhov loj me me ferrule (ob leeg 1.25mm), tab sis siv thawb- rub es tsis txhob latch- xauv. Hauv peb 10+ xyoo ntawm kev tsim khoom, peb tau pom MU yog qhov tshwj xeeb tshaj yog nrov hauv DWDM systems thiab Japanese telecom networks uas yuav tsum muaj NTT compatibility.

Q: Vim li cas kuv thiaj xaiv MU tshaj qhov sib txuas ntau dua LC?

A: Ua siab ncaj, yog tias koj tab tom pib tshiab, LC yog qhov kev xaiv thoob ntiaj teb rau ntau daim ntawv thov. Tab sis muaj cov xwm txheej tshwj xeeb uas MU yog txoj cai hu: yog tias koj ua haujlwm nrog NTT- cov khoom siv txheem, DWDM / CWDM systems hauv Nyiv lossis Asia, lossis kev koom ua ke nrog MU infrastructure, ces MU yog koj qhov txuas. Peb kuj pom MU siv nyob rau hauv ib co legacy telecom thiab industrial systems. Lub laub- rub lub tshuab qee tus engineers nyiam tshaj LC lub latch - nws yog qhov nrawm dua me ntsis los txuas / txiav tawm hauv qhov chaw nruj. Yog tias koj cov cuab yeej muaj MU chaw nres nkoj, qhov ntawd yog qhov tseeb koj cov lus teb!

Q: Qhov txawv ntawm APC thiab UPC polish hom rau MU patchcords yog dab tsi?

A: Qhov no yog qhov tseem ceeb kom tau txais txoj cai. UPC (Ultra Physical Contact) muaj lub tiaj tus, dome-zoo li tus txhuam nrog rov qab poob Zoo dua lossis sib npaug li 50dB - zoo kawg nkaus rau cov ntaub ntawv digital feem ntau xws li Ethernet thiab cov chaw zov me nyuam. APC (Angled Physical Contact) muaj 8-degree angled polish ua tiav rov qab poob ntau dua lossis sib npaug li 60dB, uas yog qhov tseem ceeb rau cov teeb liab analog, CATV, thiab daim ntawv thov ntev ntev uas txawm tias qhov kev xav me me tuaj yeem ua rau muaj teeb meem. Peb cov xim daj singlemode MU patchcords feem ntau tuaj hauv UPC, tab sis peb tsim cov APC versions rau cov neeg siv khoom uas xav tau qhov rov ua haujlwm poob ntxiv. Cia li nco ntsoov - tsis txhob sib xyaw APC thiab UPC connectors ua ke; lawv yuav tsis sib raug zoo thiab koj yuav ua rau cov ferrules puas.

Q: "SM SX Yellow" txhais li cas hauv cov khoom npe?

A: Cia kuv rhuav tshem qhov ntawd rau koj - nws yog qhov yooj yim zoo nkauj thaum koj paub: "SM" sawv rau Tib Hom (9/125μm fiber ntau), uas txhawb nqa ntev - kis tau tus mob ntawm 1310nm thiab 1550nm wavelengths. "SX" txhais tau tias Simplex - uas yog ib qho fiber ntau strand, as opposed to duplex uas muaj ob fibers. Thiab "Daj" yog kev lag luam- qauv tsho xim rau singlemode fiber ntau rau TIA-598 tus qauv. Yog li thaum koj pom "SM SX Yellow," koj paub tias koj tau txais ib leeg-fiber, singlemode patchcord nrog tus qauv daj tsho uas txhua tus kws tshaj lij yuav paub tam sim. Peb kuj ua multimode versions hauv txiv kab ntxwv (OM1 / OM2) thiab aqua (OM3 / OM4) yog qhov koj xav tau.

Q: Dab tsi ntxiv qhov poob kuv yuav tsum tau los ntawm koj MU patchcords?

A: Peb spec peb cov MU patchcords tsawg dua lossis sib npaug ntawm 0.3dB qhov poob, uas ua tau raws li IEC, TIA / EIA, thiab Telcordia cov qauv. Tab sis kuv mam li cia koj nyob rau hauv ib yam dab tsi - feem ntau units peb nkoj ntsuas qhov nruab nrab ntawm 0.15-0.2dB vim peb 100% optically sim txhua txhua patchcord ua ntej nws tawm ntawm peb qhov chaw. Rau kev poob rov qab, koj tab tom saib Ntau dua lossis sib npaug rau 60dB rau APC polish thiab Ntau dua lossis sib npaug rau 50dB rau UPC. Kev sib hloov (kev sib txuas nrog lwm cov MU txuas) yog tsawg dua lossis sib npaug rau 0.2dB. Cov specs no tseem ceeb rau koj qhov txuas kev suav nyiaj txiag, tshwj xeeb tshaj yog tias koj tab tom cascading ntau qhov kev sib txuas. Xav tau cov ntaub ntawv xeem rau ib pawg tshwj xeeb? Tsuas nug - peb khaws cov ntaub ntawv.

Q: MU patchcords puas tuaj yeem tuav 10G nrawm lossis siab dua?

A: kiag li - fiber ntau nws tus kheej tsis yog qhov nrawm nrawm, koj lub transceivers yog. Peb singlemode MU patchcords (9/125μm OS2) tau yooj yim txhawb 1G, 10G, 25G, 40G, thiab txawm tias 100G kis tau tus mob. Rau singlemode ntawm 1310nm, koj tab tom saib ntawm kev sib kis mus txog 10km; ntawm 1550nm, koj tuaj yeem ncav cuag 40km lossis ntau dua nyob ntawm koj cov khoom siv. Peb kuj muaj ntau hom versions (50/125 thiab 62.5/125) rau luv luv - ncav cuag, siab dua - bandwidth daim ntawv thov. Yog tias koj tab tom tsim cov vaj tse niaj hnub no, singlemode yog yav tom ntej - pov thawj rau txawm tias qhov ceev yuav los tom ntej.

Q: Dab tsi yog qhov tsawg kawg nkaus khoov vojvoog, thiab nws puas tseem ceeb rau kev teeb tsa siab -?

A: Qhov no yog ib qho tseem ceeb heev rau tiag tiag - ntiaj teb kev teeb tsa. Peb cov MU patchcords muaj qhov tsawg kawg nkaus khoov vojvoog ntawm 10mm nyob rau hauv load - txog txoj kab uas hla ntawm ib tug cwj mem. This is particularly valuable in high-density patch panels where space is tight and cables inevitably get bent. Mus rau hauv qab qhov tsawg kawg nkaus khoov vojvoog ua rau kom muaj kev cuam tshuam thiab tuaj yeem ua rau cov fiber ntau puas. Nyob rau hauv cov ntawv thov uas MU excels - zoo li cramped DWDM chassis backplanes - uas 10mm khoov vojvoog muab rau koj saj zawg zog thaum tuav lub teeb liab kev ncaj ncees. Uas tau hais tias, muab koj cov cables tsim nyog slack thiab siv kev tswj cable kom raug thaum twg los tau.

Q: Dab tsi cable tsho xaiv koj muab, thiab kuv yuav xaiv qhov twg?

A: Peb muab PVC thiab LSZH (Low Smoke Zero Halogen) tsho hauv ntau txoj kab uas hla: 0.9mm, 2.0mm, thiab 3.0mm. Nov yog yuav ua li cas xaiv: PVC yog tus nqi- siv tau thiab ua haujlwm zoo rau cov qauv kev teeb tsa. LSZH yog qhov koj xav tau rau qhov chaw plenum, cov tsev pej xeem, kev thauj mus los, thiab txhua qhov chaw hluav taws kub muaj kev txhawj xeeb - nws tsis tawm cov pa phem thaum hlawv. Rau txoj kab uas hla, 0.9mm yog qhov compact tshaj plaws rau qhov chaw nruj, 2.0mm yog peb cov neeg nyiam tshaj plaws - nyob ib puag ncig kev xaiv, thiab 3.0mm muab cov kav ntev thiab yooj yim tuav. Peb tseem tuaj yeem muab Riser (OFNR) thiab Plenum{12}} cov kev xaiv ntsuas nyob ntawm koj lub tsev lis dej num. Cia li qhia rau peb paub koj ib puag ncig thiab peb mam li pom zoo cov spec.

Q: Koj MU patchcords puas ua raws li NTT thiab JIS cov qauv?

A: Yog - qhov no yog ib qho ntawm cov laj thawj tseem ceeb uas cov neeg siv khoom xaiv MU txuas tshwj xeeb. Peb cov MU patchcords tau ua raws li NTT-MU hardware specifications thiab JIS (Japanese Industrial Standards). Qhov no ua kom muaj kev sib txuam zoo nrog NTT cov khoom siv network thiab lwm yam kev lag luam hauv Nyij Pooj. Peb tau muab MU cov khoom lag luam rau Asian telecom tswv rau ntau tshaj 10 xyoo, yog li peb nkag siab txog cov kev cai tshwj xeeb. Tag nrho peb cov khoom tseem ua tau raws li IEC, TIA / EIA, thiab Telcordia cov qauv rau kev sib raug zoo thoob ntiaj teb.

Q: Koj puas tuaj yeem kho qhov ntev, xim, thiab cov khoom sib txuas ua ke?

A: Qhov ntawd yog ib qho ntawm peb lub zog ua cov chaw tsim khoom. Peb muab cov kev cai ntev los ntawm luv luv li 0.5m mus rau txhua yam koj xav tau - tsuas yog qhia hauv koj qhov kev txiav txim. Rau hybrid cables, peb tuaj yeem ua MU rau LC, MU rau SC, MU rau FC, lossis ib qho kev sib xyaw uas koj xav tau. Jacket xim tuaj yeem hloov kho dua li tus qauv daj (rau SM) thiab txiv kab ntxwv / aqua (rau MM) yog tias koj xav tau xim -coding rau cable tswj. Peb kuj muab cov kev pabcuam OEM suav nrog kev tsim khoom lag luam, ntim khoom, thiab kev sau ntawv ntiag tug. Lub sij hawm ua tus thawj coj rau kev txiav txim yog 2-4 lub lis piam nyob ntawm seb muaj pes tsawg thiab specifications. Tsuas yog hu rau peb pab neeg muag khoom nrog koj cov kev xav tau.

Cim npe nrov: Tuam Tshoj fiber optic mu patchcord sm sx daj, Tuam Tshoj fiber optic mu patchcord sm sx daj manufacturers, lwm tus neeg, Hoobkas

Xa kev nug

(0/10)

clearall