Dab tsi Ua Qhov 12 Core Patch Cord txawv
SC fiber optic thaj qaum yog ib qho me me compact thaj cable nrov heev siv nyob rau hauv ntau daim ntawv thov. Cov kev daws teeb meem hauv lub network no suav nrog kev sib txuas lus hauv xov tooj, LANs, cov ntaub ntawv ua haujlwm, kev txiav cov cuab yeej thiab cov chaw faib khoom. SC patch cords yog tsim los xa cov kev daws teeb meem ceev Ethernet hauv Gigabit daim ntawv thov thiab ATM daim ntawv thov nrog qhov chaw tsawg dua.
1 Cable=6 Duplex Links
Consolidates 6 duplex kev sib txuas rau hauv ib lub rooj sib txoos, txiav cov kab ntau los ntawm ~ 60%. Tsawg clutter hauv kojterminal lub thawvlos yog ODF txhais tau tias kev taug qab yooj yim dua thiab kho sai dua.
12-Color Fibre Identification
Txhua sab hauv fiber ntau ua raws li TIA / EIA-598 xim code (Blue → Aqua), yog li koj pinpoint txhua channel tam sim ntawd. Lub tsho txiv kab ntxwv sab nraud kom meej meej cais qhov no los ntawm dajib hom kab cordsntawm qhov chaw.
SC Push-Pull × 12 Chaw nres nkoj
Tag nrho 12 channel siv SC / UPC connectors nrog ceramic ferrules. Push- rub latch tiv thaiv kev sib tsoo rub tawm - tawm - qhov tseem ceeb thaum 12 fibers sib koom ib lub cable. Pairs ncaj qha nrog tus qauvSC adaptersntawm tej vaj huam sib luag.
Specification
| Parameter | Chav tsev | FC, SC, LC / Armored fiber ntau thaj qaum | ST, MU | MT-RJ, MPO | E2000 | ||||||||
| SM | MM | SM | MM | SM | MM | SM | |||||||
| PC | UPC | APC | PC | PC | UPC | PC | PC | UPC | PC | PC | APC | ||
| Insertion poob (tseem) | dB | Tsawg dua los yog sib npaug li 0.3 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.3 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.3 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.3 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.3 | Tsawg dua los yog sib npaug li 0.3 |
| Rov qab poob | dB | Ntau dua lossis sib npaug li 45 | Ntau tshaj los yog sib npaug rau 50 | Ntau tshaj los yog sib npaug rau 60 | Ntau tshaj los yog sib npaug rau 30 | Ntau dua lossis sib npaug li 45 | Ntau tshaj los yog sib npaug rau 50 | Ntau tshaj los yog sib npaug rau 30 | Ntau dua lossis sib npaug li 45 | Ntau tshaj los yog sib npaug rau 50 | Ntau dua lossis sib npaug li 35 | Ntau dua lossis sib npaug li 55 | Ntau dua lossis sib npaug li 75 |
| Ua haujlwm wavelength | nm | 1310, 1510 | 1310, 1510 | 1310, 1510 | 1310, 1510 | ||||||||
| Exchangeability | dB | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | ||||||||
| Kev vibration | dB | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | Tsawg dua los yog sib npaug li 0.2 | ||||||||
| Ua haujlwm kub | degree | -40~75 | -40~75 | -40~75 | -40~75 | ||||||||
| Cia kub | degree | -45~85 | -45~85 | -45~85 | -45~85 | ||||||||
| Cable txoj kab uas hla | mm | φ3.0, φ2.0, φ0.9 | φ3.0, φ2.0, φ0.9 | φ3.0, φ2.0, φ0.9 | φ3.0, φ2.0, φ0.9 | ||||||||
Nta
Singlemode lossis Multimode SC, Riser lossis Plenum Rated
Peb muab SC fiber ntau optic cable sib dhos, nrog ib hom (9/125 OS1, OS2), duplex thiab multimode (50/125 thiab 62.5/125) kev xaiv. Koj tuaj yeem xaiv yog tias nws yog rau daim ntawv thov riser lossis kev sib txuas plenum lossis yog tias koj xav kom nws ua tiav, koj tuaj yeem tiv tauj peb kom paub ntau ntxiv txog peb cov kev pabcuam OEM / ODM rau SC thaj qaum.
Yooj yim thiab yooj yim rub tawm
Ua nrog ib qho yooj yim snap nyob rau hauv configuration, SC kev sib txuas yog nruab nrog xauv mechanisms uas zoo ib yam li cov tuav tuav ntawm ib tug RJ45 connector. Tam sim no nws yog ib qho yooj yim mus txuas thiab disconnect lub connector ntawm lub cuab yeej. Lub xauv tabs yog txhaj tshuaj- molded nrog txhim khu kev ruaj ntseg nyob rau hauv tiv thaiv rub, hom, snags, thiab cuam tshuam thaum lub sij hawm cabling installation thiab tu.
3
Muaj kev nyab xeeb thiab kuaj fiber ntau los ua ke nrog qis qis qis
Peb lub patch cords yog 100% optically tshuaj xyuas thiab kuaj kom coj cov kev nkag qis tsis tshaj 0.02 dB.
Daim ntawv thov

- OLT-rau-ODF patching nyob rau hauv central chaw ua hauj lwm thiab PON txee
- Campus LAN qaum siv OM1/OM2/OM3/OM4 multimode fiber ntau
- Tsim cov riser kev sib txuas ntawm MDF thiab IDF txee
- Kab rov tav cabling consolidation nyob rau hauv cov txheej txheem cabling tej yaam num

- Headend optical transmitter thiab receiver patching ntawm 1310/1550 nm
- Hub-kev sib txuas ntawm qhov chaw rau HFC faib hauv cheeb tsam
- RF- dhau- fiber ntau txuas hauv analog thiab digital CATV networks
- Cov teeb liab saib xyuas kais cov ntsiab lus rau kev kuaj xyuas lub zog kho qhov muag

- DWDM/CWDM multiplexer-rau-ODF patching hauv cov cab kuj- qib networks
- Wireless puag chaw nres tsheb backhaul - BBU rau RRU fiber ntau consolidation
- Metro-ring interconnection ntawm co- chaw nyob
- Ntau- tus neeg teb xov tooj ODF cross- txuas hauv nruab nrab tus tswv tsev ib puag ncig

- Neeg rau zaub mov-rau- hloov fiber ntau interconnection nyob rau sab saum toj- ntawm -rack deployments
- SAN ntaub ntoo khaub lig- txuas rau thaj chaw cia khoom
- High-ntaus vaj huam sib luag consolidation nyob rau hauv colocation data centers
- Kab laug sab-nplooj ntaub cabling nyob rau hauv huab thiab hyperscale ib puag ncig

- OTDR thiab kho qhov muag fais fab ntsuas kev sib txuas
- Kev tsim khoom- kab kawg- kev tshuaj xyuas lub ntsej muag thiab kev pov thawj qhov poob
- Batch kuaj ntawm cov tshiab txuas fiber ntau txuas thaum ua haujlwm
- Field troubleshooting - common connector fault isolation
FAQ
Q: Vim li cas thiaj xaiv 12 core breakout tshaj 6 duplex thaj qaum?
A: Ib lub cable hloov rau 6, txo cov ntim cable los ntawm ~ 60%. Qhov chaw nres nkoj nrawm dua, zoo dua airflow hauv cov khoom, thiab tib qhov kev ua tau zoo ntawm txhua qhov channel.
Q: Kuv puas tuaj yeem tau txais SC ntawm ib kawg thiab LC ntawm lwm qhov?
A: Yog - peb txhawb hybrid configs zoo li SC-LC, SC-FC, thiab SC-ST ntawm 12 core breakout cables, ntxiv rau hom polished (UPC/APC). Saib pebconnector xaiv.
Q: Yuav ua li cas yog 12 fibers xim -coded hauv?
A: Lawv ua raws TIA / EIA-598: Xiav, Txiv kab ntxwv, Ntsuab, Xim av, Slate, Dawb, Liab, Dub, Daj, Violet, Rose, Aqua. Standard sequence rau instant qhia thaum lub sij hawm patching.
Q: PVC lossis LSZH - Kuv yuav xaiv lub tsho twg?
A: PVC rau txheej txheem sab hauv tsev. LSZH rau cov chaw nyob ze lossis cov chaw pej xeem (cov chaw zov me nyuam, tsev kho mob) uas muaj pa luam yeeb muaj teeb meem. Cov lej European (EN 50173) feem ntau ua haujlwm LSZH. Tsis muaj qhov sib txawv hauv kev ua haujlwm kho qhov muag.
Q: Puas yog txhua tus cable raug kuaj?
A: Yog. Txhua chav tsev yog 100% Hoobkas kuaj xyuas qhov poob, rov qab poob, thiab kawg -fab geometry. Daim ntawv qhia txog kev xeem tus kheej suav nrog.
Hot Tags: 12 Core SC Multimode Txiv kab ntxwv Fiber Optic Patch Cord, Tuam Tshoj 12 Core SC Multimode Txiv kab ntxwv Fiber Optic Patch Cord manufacturers, lwm tus neeg, Hoobkas







