Sab nraum zoov fiber ntau thaj cable rau FTTA (Fiber rau lub kav hlau txais xov) yog ruggedized, weatherproof fiber optic los ua ke uas txuas baseband units (BBUs) nyob rau hauv pem teb mus rau tej thaj chaw deb xov tooj cua units (RRUs) mounted rau ntawm tes yees. Cov cables no siv IP67- ntsuas cov khoom siv dej tsis sib haum - feem ntau PDLC, ODVA, NSN Boot, lossis FullAXS - thiab tau tsim nrog UV-resistant LSZH lossis TPU tsho kom muaj sia nyob ntau xyoo ntawm sab nraum zoov. Yog tias koj tab tom siv 4G LTE lossis 5G cov chaw nres tsheb, sab nraum FTTA thaj cable koj xaiv ncaj qha txiav txim siab qhov kev ntseeg siab, teeb liab zoo, thiab ntau npaum li cas koj cov neeg coob yuav tsum nce rov qab mus rau ntauwd.

Vim li cas FTTA Hloov Coax - thiab Vim Li Cas Patch Cable Tseem Ceeb Tshaj
Kev hloov ntawm coaxial feeder khiav mus rau fiber ntau -raws li FTTA architecture tsis yog xaiv tau. Nws raug yuam los ntawm physics. Ib txwm coaxial cables nruab nrab ntawm lub hauv paus chaw nres tsheb vaj tse thiab nws cov kav hlau txais xov poob ntau RF teeb liab lub zog dhau qhov deb, nrog cov kev ua tau zoo feem ntau txwv rau kwv yees li 100 meters. Fiber optic cable nqa cov teeb liab 10 mus rau 20 mais nrog kev poob qis. Hauv FTTA layout, RRU zaum ze ntawm tus kav hlau txais xov thiab ua haujlwm digital-rau-analog hloov dua siab tshiab ntawm-site. Cov fiber ntau khiav los ntawm av mus rau ntauwd saum toj yog qhov txuas pem hauv ntej, thiab sab nraum zoov patch cable yog qhov kawg mating point - ib feem uas tau ntsaws, unplugged, weathered, thiab stressed ntau tshaj li lwm yam ntawm fiber ntau txoj kev.
Tias yog vim li cas, los ntawm kev tsim khoom thiab kev muag khoom, sab nraum zoov FTTA thaj cables tsim ntau RMA kev nug ntau dua li yuav luag txhua yam khoom siv fiber ntau. Lub cable nws tus kheej tsis tshua ua tsis tau. Dab tsi ua tsis tau yog qhov sib txuas sib txuas, kev ruaj ntseg ntawm cov cuab yeej ntawm qhov kev ntxhov siab, lossis qhov kawg - yuav luag txhua lub sijhawm vim tias cov cable tsis raug cai tau teev tseg rau ib puag ncig, lossis txoj cai cable raug teeb tsa tsis raug.
Dab tsi Ua Rau Sab Nraud FTTA Cable Sib txawv ntawm Cov Qauv Patch Cord
Tus qauv sab hauv LC-rau-LC duplex jumper yuav tsis kav ib hlis ntawm lub ntsej muag ntauwd. Qhov sib txawv yog cov qauv, tsis yog tshuaj pleev ib ce.
Lub cev cable nyob rau sab nraum zoov FTTA sib dhos yog feem ntau yog 5.0 hli lossis 7.0 hli GYFJH- hom kev tsim kho: ob hom fiber ntau cores (G.657.A1 lossis G.657.A2 khoov- tsis hnov tsw fiber ntau) ncig los ntawm aramid yarn zog cov tswv cuab ntawm lub cev, thiab lub cev muaj zog ntawm LS ntawm lub cev muaj zog, thiab lub cev muaj zog los yog TPU. LSZH ua tau raws li cov nplaim hluav taws xob sib txuas- cov kev cai retardancy yam tsis tso pa tawm. TPU yog nruj dua tiv thaiv puas thiab rov flexing - peb feem ntau pom zoo rau nws rau kev teeb tsa qhov twg cov cable tau dhau los ntawm cov kav dej nruj los yog rub los ntawm cov tswv cuab ntawm cov tswv cuab ntawm ntauwd.
Nyob rau hauv txhua rooj plaub, ib tug waterproof connector vaj tse encloses lubLC Duplex Fiber Optic Connectorinterface. The housing mates with a corresponding bulkhead adapter on the RRU or junction box, and the locking mechanism compresses an O-ring gasket to achieve IP67 ingress protection - meaning complete dust-tightness and resistance to temporary water immersion up to one meter.
Plaub Connector Systems koj yuav ntsib tiag tiag
Qhov no yog ntu feem ntau cov neeg yuav khoom tsis raug, yog li nws tsim nyog siv sijhawm. Sab nraum zoov FTTA connectors tsis hloov pauv. Kev txiav txim siab tsis ncaj ncees lawm txhais tau tias koj lub cev tsis tuaj yeem ua phooj ywg nrog lub xov tooj cua lub taub hau chaw nres nkoj - thiab peb pom qhov no tshwm sim ntau dua li txhua tus neeg hauv kev lag luam nyiam lees paub.
PDLC (Push-Pull Duplex LC)yog qhov tseem ceeb interface rau ZTE, Huawei, thiab feem ntau ntawm kev xa tawm thoob ntiaj teb. Tus qauv duplex LC ferrule khub zaum hauv lub plhaub hlau cylindrical nrog lub laub- rub lub dab tshos. Kev txhim kho yog yooj yim: kho qhov tseem ceeb, thawb kom txog thaum nws nyem, tes -tighten lub txiv ntoo sab nraud. PDLC cov rooj sib txoos ua raws li IEC 61754-20 thiab ua phooj ywg nrog txhua tus qauv LC adapter ib zaug tshem tawm ntawm tsev nyob sab nraum zoov. Rau feem ntau macro cell tsim, PDLC muab qhov zoo tshaj plaws ntawm cov nqi sib npaug, lub sijhawm ua haujlwm, thiab kev pabcuam hauv thaj chaw. Nws kuj yog hom connector peb nkoj feem ntau.
ODVA (Sab nraum zoov hloov pauv hloov pauv)ua raws IEC 61076-3-106 thiab tau txais los ntawm Nokia, Samsung, thiab ntau-cov chaw muag khoom sib koom - tshwj xeeb tshaj yog nyob rau North America thiab Europe uas hla - platform interoperability yog qhov yuav tsum tau ua. ODVA txhawb peb sab hauv: duplex LC (ODVA-}DLC), simplex SC (ODVA-SC), thiab ntau fiber ntau MPO (ODVA-MPO). Lub tsev nyob sib txuas yog bulkier dua PDLC tab sis tswj kev vibration, ntsev pos huab, thiab thermal shock kuaj tau zoo heev.
NSN Bootyog Nokia-cov cuab yeej cuab tam tsim: cov roj hmab hloov tau yooj yim dua li tus qauv LC duplex txuas nrog lub nplhaib sib txuas. Nws yog sib zog thiab ntau compact, uas ua rau nws nrov rau lub ru tsev me me hlwb thiab sab hauv tsev / sab nraum zoov hybrid khiav. Kev lag luam - tawm yog tiag tiag, txawm li cas los xij. Cov roj hmab khau raj foob degrades sai dua nyob rau hauv kev tiv thaiv UV raug piv rau cov vaj tse hlau tag nrho. Rau cov chaw ntauwd hauv cov suab puam lossis huab cua sov, peb feem ntau coj cov neeg siv khoom mus rau PDLC lossis ODVA hloov.
FullAXStau tsim tshwj xeeb rau Ericsson Radio System platforms. Lub laub lub voj voos -rub tsev tso cai rau ib qho - tes ua haujlwm nrog cov hnab looj tes, thiab cov plua plav sib xyaw ua ke tiv thaiv qhov kawg ntawm kev sib txuas. Yog tias koj tab tom ua haujlwm ntawm Ericsson- muaj ntauwd lossis ib qho sib koom -RAN site uas suav nrog cov xov tooj cua Ericsson, FullAXS yuav raug teev nyob rau hauv phau ntawv qhia kev teeb tsa.
Qhov kev txiav txim ntau tshaj plaws uas peb pom: ib tus neeg siv khoom xa RFQ rau "sab nraum zoov LC thaj cables rau FTTA" yam tsis tau qhia txog qhov txuas txuas. Qhov ntawd zoo li kev xaj cov log tsheb yam tsis tau qhia txog tus qauv ntsia liaj qhov rooj. Ib txwm paub meej tias RRU chaw nres nkoj hom - PDLC, ODVA, NSN, lossis FullAXS - ua ntej hais lossis yuav khoom.
Specifications uas cais ib tug zoo Cable los ntawm ib tug teeb meem Cable
- Fiber ntau:G.657.A1 tib - hom yog tus qauv. G.657.A2 tso cai rau kev khoov nruj dua (7.5 mm qhov tsawg kawg nkaus lub vojvoog vs . 10 mm) thiab tsim nyog qhia rau cov pej thuam kaw - sab saum toj enclosures.
- Cable sab nraud txoj kab uas hla:5.0 hli rau luv luv, tsis tshua muaj khiav khiav qhov yooj yooj yim teeb meem . 7.0 hli rau ntsug pej thuam rub tshaj 30 meters - qhov ntxiv tensile npoo tsis xaiv ntawm cov ntev.
- Tensile zog:500 N yam tsawg kawg nkaus luv luv -term. Peb ntsuas peb cov rooj sib txoos ntawm 600 N, uas muab lub ntsiab lus tseem ceeb hauv lub taub hau thaum muaj ntauwd rub qhov twg cable hnyav thiab cua thauj khoom ua ke.
- Crush resistance:1000 N / 100 mm yog zoo rau kev tiv thaiv conduit. Rau cov hlua khi ncaj nraim rau cov hlau ntauwd, qhia meej 2000 N / 100 mm - ntog dej khov, cov cuab yeej, thiab cov kauj ruam tsis sib xws- thaum lub sijhawm tu yog txhua yam kev phom sij tiag tiag.
- Insertion poob:Kev sib dhos ua tiav nrog rau ob qho kev sib txuas yuav tsum ntsuas qis dua 0.3 dB ib khub niam txiv. Txhua cable peb nkoj suav nrog ib tus neeg lub Hoobkas kuaj daim ntawv tshaj tawm xyuas qhov no.
- Ua haujlwm kub:-40℃rau +70℃yog lub hauv paus. Cov chaw suab puam lossis qhov chaw equatorial yuav tsum tau hais qhia +85℃ntsuas cov rooj sib txoos.
- IP ntsuam xyuas:IP67 yog kev lag luam pem teb. IP68 yog pom zoo rau hauv av- theem vault nkag los yog ntug hiav txwv yees qhov twg ntsev tsuag thiab kev sib cuag ntawm cov dej nyob ntev yog niaj hnub.
Ib qho kev ceeb toom ntawm cov lus qhia tshwj xeeb uas feem ntau tau saib tsis pom: cov khoom siv armor tube. Stainless hlau armor tuav nws txoj kev ncaj ncees nyob rau hauv ntug dej hiav txwv, siab - av noo, thiab muaj ib puag ncig. Zinc-plated carbon steel armor yog pheej yig dua tab sis tuaj yeem corrode nyob rau hauv ob mus rau peb xyoos hauv ntsev- laden cua. Yog tias koj tab tom xa mus rau ze ntawm ntug dej hiav txwv lossis hauv thaj tsam hnyav - kev lag luam, nug koj tus neeg muag khoom tshwj xeeb uas siv cov cuab yeej cuab tam.
Installation yuam kev uas tsim cov teb rov qab feem ntau
Peb taug qab kev lees paub kev lees paub thiab RMA cov ntaub ntawv thoob plaws peb cov khoom lag luam FTTA sab nraum zoov. Peb tus qauv tsis ua haujlwm suav nrog feem ntau ntawm cov khoom xa rov qab - thiab tsis muaj ib qho ntawm lawv yog kev tsim khoom.
Cov kab mob kis tau los ntawm qhov pib mating.Ib qho hmoov av ib leeg ntawm LC ferrule taub tuaj yeem nce qhov kev poob qis los ntawm 0.5 dB lossis ntau dua. Ntawm lub platform cua daj cua dub, cov khib nyiab pov tseg rau ntawm qhov kawg ntawm qhov kawg hauv vib nas this. Kev kho yog yooj yim tab sis tsis yog- sib tham: ntxuav txhua lub ntsej muag nrog ib qho - nyem lub tshuab ntxhua khaub ncaws lossis lint- dawb IPA so tam sim ua ntej sib yuav, thiab khaws cov plua plav plua plav mus txog lub sijhawm kawg. Qhov no ib leeg yuav tshem tawm kwv yees li ib feem peb ntawm cov lus tsis txaus siab "siab" uas peb tau txais.
Khoov vojvoog kev ua txhaum cai thaum lub sij hawm txoj kev cable.Cov neeg tsim khoom qee zaum ua kom ntse 90-degree khoov rau txoj kab hluav taws xob nyob ib puag ncig cov tswv cuab lossis hauv cov ntaub ntawv. Qhov tshwm sim macrobend poob yuav tsis tshwm sim ntawm OTDR kab tam sim ntawd, tab sis nws hnyav zuj zus vim qhov kub thiab txias ua rau qaug zog cov txheej fiber ntau dhau lub hli tom ntej. Rau 7.0 hli FTTA cable, tuav tsawg kawg yog 70 hli static khoov vojvoog (10 × cable OD) thiab 140 hli dynamic khoov vojvoog thaum rub.
Kev them nyiaj yug tsis txaus rau ntawm tus pej thuam.Tsis muaj kev txhawb nqa cable spans ntawm cov ntsiab lus txuas ua raws li cua sails. Lub cyclic mechanical kev nyuaj siab concentrates ntawm lubconnector termination point, accelerating qaug zog tawg nyob rau hauv lub armor tube. Kev ruaj ntseg cables rau ntauwd hlau siv UV- ntsuas cov hlau tsis muaj hlau sib txuas ntawm lub sijhawm tsis pub ntau tshaj ib 'meter'. Ntawm qhov chaw saum ru tsev, taug kev los ntawm cov kav dej tsis muaj huab cua nyob qhov twg los tau.
Yuav Ua Li Cas Xaiv Txoj Cai Sab Nraud Sab Nraud FTTA Patch Cable - Kev txiav txim ib ntus

Tsis yog daim ntawv tshuaj ntsuam xyuas dav dav, ntawm no yog qhov kev txiav txim siab tiag tiag uas tsis txhob muaj qhov yuam kev feem ntau:
Kauj Ruam 1: Txheeb xyuas RRU connector chaw nres nkoj.Txheeb xyuas cov ntaub ntawv cov khoom siv lossis cov ntawv qhia kev teeb tsa. Qhov no muab rau koj hom connector - PDLC, ODVA, NSN Boot, lossis FullAXS. Tsis txhob xav tias raws li tus neeg muag khoom lag luam ib leeg; qee tus neeg khiav dej num qhia tias tsis yog - cov khoom sib txuas ua ntej hauv lawv cov qauv xa tawm.
Kauj Ruam 2: Ntsuas txoj kev routing, tsis yog qhov ncaj - kab nrug.Ib tug 60-meter pej thuam tsis txhais hais tias 60-meter cable. Tus account rau kab rov tav khiav hauv lub vaj tse, txoj hauv kev raws tus pej thuam ntsej muag nrog rau kev taug kev nyob ib puag ncig cov kev cuam tshuam, thiab kev pabcuam voj voog ntawm 1 txog 2 meters ntawm RRU kawg. Txiav txim siab qhov kev cai ntev ntev - cov coils ntau dhau los tsim qhov tsis tsim nyog nkag thiab ntes cua.
Kauj Ruam 3: Sib phim txoj kab uas hla mus rau qhov chaw kho tshuab.5.0 hli rau kev tiv thaiv los yog luv luv khiav . 7.0 hli rau cov pej thuam nthuav tawm -lub ntsej muag khiav tshaj 30 meters qhov tensile load thaum lub sij hawm installation yog ib qho tseem ceeb.
Kauj Ruam 4: Paub meej ib puag ncig.Ntug hiav txwv lossis kev lag luam? Qhia meej stainless hlau armor thiab IP68. Standard inland pej thuam? Zinc-plated armor thiab IP67 feem ntau yog txaus. Qhov kub thiab txias npaum li cas? Xyuas kom tseeb tias lub tsho thiab cov khoom sib txuas cov ntaub ntawv raug ntsuas raws li.
Kauj Ruam 5: Thov ib tus qauv nrog cov ntawv xeem ua ntej ntim xaj.Ntsuas qhov poob qis ntawm -qhov chaw nrog koj tus kheej cov cuab yeej. Tshawb xyuas covfiber ntau optic adaptermating interface rau concentricity thiab endface geometry. Tus neeg muag khoom uas tsis kam xa cov qauv kuaj tsis yog tus xa khoom koj xav tau ntawm 500-cable ntauwd rollout.
5G Fronthaul thiab Nws txhais li cas rau kev xaiv Cable
5G NR thiab 5G tawm tshiab- Cov txheej txheem qib siab tsis hloov pauv lub hauv paus physics ntawm sab nraum zoov FTTA thaj cables, tab sis lawv hloov qhov ntsuas. Loj MIMO kav hlau txais xov arrays nrog 32T32R los yog 64T64R configurations xav tau fiber ntau khub rau ib sector tshaj legacy 2T2R xov tooj cua. Qee lub kav hlau txais xov siv tam sim no xav tau yim lossis kaum ob qhov chaw nres nkoj fiber ntau, uas thawb kev thov kom siab dua - suav cov rooj sib txoos lossisPLC fiber ntau optic splitterkev faib tawm ntawm lub hauv paus ntauwd.
Qhov ntom ntawm cov hlwb me me - tshwj xeeb hauv C-Band thiab mmWave spectrum - kuj yog qhov sib npaug ntawm qhov kawg. Kev xa tawm hauv nroog hnyav tuaj yeem nruab 50 mus rau 100 lub xov tooj me me ntawm ib square km, txhua qhov yuav tsum tau ua ntej - txiav tawm sab nraum zoov duplex thaj cable. Ntawm qhov ntim ntawd, ntsaws- thiab- ua si cov rooj sib txoos nrog lub Hoobkas- cov ntaub ntawv kuaj xyuas tau lees paub dhau los ua qhov tseem ceeb rau kev xa tawm raws sijhawm.
Kuj tseem muaj kev txaus siab rau hybrid FTTA / PTTA cables uas sib txuas cov fiber ntau thiab DC fais fab txuas hauv ib lub tsho, txo tag nrho cov cable suav ntawm tus pej thuam. Cov no tsim nyog ntsuas rau kev tsim kho tshiab - tab sis lawv yuav tsum tau ua tib zoo txheeb xyuas qhov sib raug zoo nrog ob lub xov tooj cua lub taub hau lub zog tawm tswv yim thiab cov fiber ntau cuam tshuam, yog li lawv tseem tsis tau poob - hloov pauv cov fiber ntau thiab lub zog khiav ntawm txhua qhov chaw.

Where the Outdoor Patch Cable Meets the Rest of Your Fiber Path
Ntawm lub hauv paus ntauwd, sab nraum zoov FTTA thaj cables feem ntau xaus rau hauv huab cua tsis zoofiber optic davhlau ya nyob twg box- qhov hloov pauv ntawm tus pej thuam- lub ntsej muag thaj qaum thiab sab hauv lub cev fiber ntau txuas rov qab mus rau BBU. Lub thawv zoo spec'd terminal lees txais cov chaw nres nkoj tsis muaj dej tsis sib haum rau sab nrauv thiab tus qauv LC lossis SC adapters nyob rau sab hauv, nrog cov tais sib txuas thiab cov strain nyem rau cov khoom xa tuaj.
Rau peb qhov chaw ib txwm-sector macro site nrog ob tus neeg nqa khoom ib ntu, npaj rau tsawg kawg rau qhov chaw nres nkoj fiber ntau. Spec lub thawv nrog headroom rau yim los yog kaum ob kom tsis txhob muaj kev sib pauv enclosures thaum tus neeg teb xov tooj ntxiv cov cab kuj los yog hloov mus rau ib tug siab dua -fiber- suav xov tooj cua. IP65 yog qhov ntsuas qhov tsawg kawg nkaus rau qhov thaiv nws tus kheej; IP68 yog qhov zoo dua nyob rau theem av hauv dej nyab- thaj chaw uas yooj yim.
Tib -Mode vs. Multimode: Tsis muaj kev sib cav rau FTTA
Txhua tus neeg muag khoom khoom loj qhia ib zaug xwb -mode fiber rau FTTA fronthaul. Cov laj thawj yog nyob deb thiab bandwidth headroom. Lub macro ntauwd khiav yuav yog 200 meters; ib tug C-RAN architecture nrog centralized BBU pas dej tauv mus rau ob peb kilometers. Tib -hom OS2 fiber ntau ntawm 1310 nm ua haujlwm txhua qhov no nrog kev txo qis qis dua 0.35 dB / km. Multimode ua tsis tau. Tus nqi ib -meter sib txawv ntawm ib qho - hom thiab multimode sab nraum zoov cable yog qhov tsis txaus ntseeg. Rau ib qho kev tsim FTTA tshiab, ib qho -hom G.657.A1 tsuas yog cov lus pom zoo tsim nyog.
Cov lus nug nquag
Q: Qhov txawv ntawm Ib Sab Hauv Tsev Fiber Patch Cable Thiab Sab Nraud FTTA Patch Cable yog dab tsi?
A: Sab hauv tsev fiber ntau optic thaj qaum siv tus qauv PVC lossis LSZH lub tsho thiab cov khoom sib txuas uas tsis muaj kev tiv thaiv rau kev tswj hwm ib puag ncig. Sab nraum zoov FTTA thaj cable ntxiv UV- tiv thaiv lub tsho tiv thaiv, kauv hlau armor, aramid yarn tensile cov tswv cuab, thiab IP67-rated waterproof connector vaj tse engineered rau -40℃rau +75 degree, ncaj qha los nag, cua loading, thiab xyoo ntawm ultraviolet raug.
Q: Ua li cas PDLC Thiab ODVA Connectors Sib Piv Rau Sab Nraum FTTA Siv?
A: Ob leeg ua tiav IP67 ib puag ncig kev sib khi thiab lub tsev qauv duplex LC ferrule cuam tshuam sab hauv. PDLC siv lub cylindrical thawb- rub lub plhaub hlau thiab dominates deployments nrog Suav- xov tooj cua tsim. ODVA ua raws li IEC 61076-3-106 nrog rau lub voj voog kaw uas txhawb nqa LC, SC, thiab MPO ntau yam, ua kom muaj ntau yam rau ntau qhov chaw muag khoom ntauwd. ODVA feem ntau raug nqi me ntsis ntxiv tab sis muaj kev sib tw dav dua. Qhov kev xaiv yuav luag ib txwm hais los ntawm RRU chaw nres nkoj specification, tsis yog tus kheej nyiam.
Q: Dab tsi IP Rating Yuav Tsum Tau Sab Nraud FTTA Cable Muaj?
A: IP67 yog tus qauv kev lag luam - tag nrho cov plua plav tiv thaiv thiab tiv thaiv dej rau ib ntus. Rau cov pej thuam hauv thaj tsam dej nyab, thaj chaw ntug dej hiav txwv nrog cov tshuaj tsuag ntsev, lossis cov chaw nkag hauv av, IP68 cov rooj sib tham muab kev tiv thaiv ntxiv rau lub sijhawm ntev.
Q: Kuv puas tuaj yeem siv Multimode Fiber Patch Cable Rau 5G FTTA?
A: Tsis pom zoo. Txhua tus neeg muag khoom loj 5G xov tooj cua qhia ib qho - hom fiber ntau rau CPRI thiab eCPRI fronthaul. Tib-hom G.657.A1 txhawb nqa qhov kev ncua deb uas xav tau los ntawm C-RAN architectures thiab raug nqi ze li ntawm ib lub 'meter' li multimode sab nraum zoov cable.
Q: Kuv Yuav Ua Li Cas Qhia Txog Kab Ntev Ntev Rau Kev Txiav Txim FTTA?
A: Ntsuas qhov tseeb routing txoj kev - ntauwd qhov siab ntxiv rau kab rov tav vaj huam sib luag khiav ntxiv rau kev taug kev nyob ib ncig ntawm kev thaiv - thiab ntxiv 1- mus rau 2-meter kev pabcuam voj ntawm RRU kawg. Kev cai ntev yog tus qauv hauv kev lag luam. Tsis txhob xaj qhov ntev ntev; coiled surplus cable tsim qhov tsis tsim nyog poob thiab catches cua ntawm lub ntsej muag ntauwd.






